Titre: Experimentation of practical new technique for single and two simultaneous diodes open faults automatic detection and localization in six diodes three phase bridge rectifier
Auteur(s): Benslimane, T.
Mots-clés: Automatic Detection
Diagnostic indices
Fault conditions
Faulty switches
Harmonic components
Minimum value
Open faults
Resistive loads
Three phasis
Three-phase bridge rectifier
Three-phase rectifiers
Algorithms
Bridge circuits
Diodes
Date de publication: 2008
Editeur: SAE International
Référence bibliographique: 2008 World Congress; Detroit, MI; United States; 14 April 2008 through 17 April 2008; Code 85694
Collection/Numéro: SAE Technical Papers 2008;
Résumé: The faulty performance of six diodes three phase rectifier is studied under one and two simultaneous open-diodes conditions. This rectifier is feeding a resistive load. The rectifier three phases currents zero harmonic components and their maximum and minimum values are used as diagnostic indices. A knowledge algorithm is based to get information on which diode is in open-switch fault condition. This algorithm testing shows that the system could not only detect the open-switch fault, but also identify the faulty switches. Presented simulation results confirm the effectiveness of the proposed methodology.
URI/URL: http://dlibrary.univ-boumerdes.dz:8080123456789/2127
Collection(s) :Communications Internationales

Fichier(s) constituant ce document :

Fichier Description TailleFormat
Experimentation of practical new technique.pdf87,49 kBAdobe PDFVoir/Ouvrir
View Statistics

Tous les documents dans DSpace sont protégés par copyright, avec tous droits réservés.

 

Valid XHTML 1.0! Ce site utilise l'application DSpace, Version 1.4.1 - Commentaires