Titre: Bond graph to digraph conversion : a sensor placement optimization for fault detection and isolation by a structural approach
Auteur(s): Alem, Said
Benazzouz, Djamel
Mots-clés: Fault detection and isolation
Sensor placement optimization
Digraph
Bond graph
Structural approach
Date de publication: 2014
Collection/Numéro: Sadhana/ Vol. 39 (2014);pp. 1151-1164
Résumé: In this paper, we consider the optimal sensors placement problem for faults detection and isolation using a novel structural and qualitative approach. This approach is based on the conversion of Bond Graph to Digraph representation of a structural system. When the fault detection and isolation of an existing system’s sensors are impossible or uncertain, a reconfiguration sensor placement of this system should be reconsidered. This paper proposes how this reconfiguration takes place by recovering all missing or redundant parts of the system. This novel approach is illustrated over a thermo-fluid application