Titre: Solar tower power plant reliability analysis using FORM method
Auteur(s): Benammar, Samir
Khellaf, Abdellah
Mots-clés: First order reliability method
Design optimization
Solar Tower Power Plant
Date de publication: 2017
Collection/Numéro: 3 éme I.C.M’ 2017 Annaba/ 26-27 Avril 2017;
Résumé: This paper presents the use of the first order reliability method (FORM) to analyze the reliability of solar tower power plant (STPP). The main steps of the HL-RF iteration method, used in FORM, have been developed and listed. The example of hypothetical solar tower power plant (STPP) has been introduced in this study in order to illustrate the FORM method. The developed mathematical model of hypothetical STPP example is used as limit state function of the studied system. Results indicate that FORM is more suitable to analyze the reliability of the STPP. So, FORM has the ability to correct the first proposed design, then to give new safe design