DSpace À propos de l'application DSpace
 

Depot Institutionnel de l'UMBB >
Publications Scientifiques >
Publications Internationales >

Veuillez utiliser cette adresse pour citer ce document : http://dlibrary.univ-boumerdes.dz:8080/handle/123456789/441

Titre: A method for measuring the photoelectric work function of contact materials versus temperature
Auteur(s): Akbi, Mohamed
Mots-clés: Contact materials
Electron work function (EWF)
Fowler’s Methods
Photoemission
Temperature dependence
Vacuum heat treatment
Date de publication: 2014
Editeur: IEEE
Collection/Numéro: IEEE Transactions on components, packaging and manufacturing technology/ Vol.4, N°8 (2014);pp.1293-1302
Résumé: The nature of the contact material plays a key role to determine the characteristics of electrical arcs and particularly those related to electronic emission. Mechanical and thermodynamic properties as well as electronic emission of such complicated alloys present a lack of reliable and accurate experimental data. The purpose of this paper is to present the development of a method for measuring photoelectric work functions of contact materials. Also reported in this paper are the results of experimental work whose purpose has been the buildup of a reliable photoelectric system and associated monochromatic ultraviolet radiations source, and the photoelectric measurement of the EWF of contact materials. As a first test of the experimental Ultra High Vacuum setup, the electron work functions (EWF) of silver contacts, namely pure polycrystalline metals that are actually used in relays, were measured photoelectrically, using both Fowler’s method of isothermal curves and linearized Fowler plots. Ultrahigh vacuum techniques were employed to obtain residual gas pressure of about 5×10−9 mbar that allows accurate and reliable photoelectric work function measurements. The EWF measured at room temperature of polycrystalline Ag contact (as commercially available) increased from 3.70 eV before heating, to 4.30 eV, and finally, stabilized at the vicinity of 4.26 eV after several vacuum heat treatments at 533 and 773 K. The EWF value obtained, i.e., 4.26 ± 0.03 eV, is in good agreement with the results found in the literature. This shows that the experimental method is valid and the experimental setup is usable. Furthermore, new photoelectric measurements versus temperature have shown a linear decrease of the EWF of silver contacts with increasing temperature, i.e., the temperature coefficient α = dφ/dt is constant and negative α = −4.58 · 10−4 eV/K in the experiment temperature range 300–780 K
URI/URL: http://dlibrary.univ-boumerdes.dz:8080/handle/123456789/441
ISSN: 2156-3950
Collection(s) :Publications Internationales

Fichier(s) constituant ce document :

Fichier Description TailleFormat
A method for measuring the photoelectric work function of contact materials versus temperature.pdf96,59 kBAdobe PDFVoir/Ouvrir
View Statistics

Tous les documents dans DSpace sont protégés par copyright, avec tous droits réservés.

 

Valid XHTML 1.0! Ce site utilise l'application DSpace, Version 1.4.1 - Commentaires