DSpace À propos de l'application DSpace
 

Depot Institutionnel de l'UMBB >
Publications Scientifiques >
Publications Internationales >

Veuillez utiliser cette adresse pour citer ce document : http://dlibrary.univ-boumerdes.dz:8080/handle/123456789/5266

Titre: A combined monitoring scheme with fuzzy logic filter for plant-wide Tennessee Eastman Process fault detection
Auteur(s): Ammiche, Mustapha
Kouadri, Abdelmalek
Bakdi, Azzeddine
Mots-clés: Principal Component Analysis
Moving Window Principal Component Analysis
Adaptive thresholds
Fault detection and diagnosis
Fuzzy logic filter
Tennessee Eastman Process
Date de publication: 2018
Editeur: Elsevier
Collection/Numéro: Chemical Engineering Science Volume 187, 21 September 2018;PP.269-279
Résumé: Principal Component Analysis (PCA) is the most common Multivariate Statistical Process Control (MSPC) method that is widely used for Fault Detection and Diagnosis (FDD). Since early abnormality detection with high accuracy is required for safe and reliable process operation, False Alarms Rate (FAR), Missed Detection Rate (MDR) and the detection time delay are the major factors that must be taken into consideration when developing any process monitoring scheme. Unfortunately, the PCA performance, with fixed limits, is weak in terms of the stated factors. In contrast, conventional Moving Window PCA (MWPCA) is an adaptive technique which updates both the PCA model and the thresholds once a new normal observation is available. Yet, MWPCA methodology still does not reduce the MDR and the detection delay. In this paper, a Modified MWPCA (MMWPCA) with Fuzzy Logic Filter (FLF) is proposed to enhance the monitoring performance of PCA. It is an adaptive approach with a fixed model that combines both aforementioned techniques. The aim of using FLF is to ensure robustness to false alarms without affecting the Fault Detection (FD) performance. The application of the proposed method has been carried out on the Tennessee Eastman Process (TEP). Hold-one and hold-five MMWPCA with FLF are applied and compared to recent FDD work in the literature. The obtained results demonstrate the superiority of the proposed technique in detecting different types of faults with high accuracy and with shorter time delay
URI/URL: http://dlibrary.univ-boumerdes.dz:8080/handle/123456789/5266
ISSN: 0009-2509
Collection(s) :Publications Internationales

Fichier(s) constituant ce document :

Fichier Description TailleFormat
AMMICHE.pdf91,29 kBAdobe PDFVoir/Ouvrir
View Statistics

Tous les documents dans DSpace sont protégés par copyright, avec tous droits réservés.

 

Valid XHTML 1.0! Ce site utilise l'application DSpace, Version 1.4.1 - Commentaires